Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Life Sci Space Res (Amst) ; 39: 67-75, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37945091

RESUMO

We report the results of the first six years of measurements of the energetic particle radiation environment on the International Space Station (ISS) with the Radiation Assessment Detector (ISS-RAD), spanning the period from February 2016 to February 2022. The first RAD was designed and built for MSL, the Mars Science Laboratory rover, also known as Curiosity; it has been operating on Mars since 2012 and is referred to here as MSL-RAD. ISS-RAD combines two sensor heads, one nearly identical to the single MSL-RAD sensor head, the other with greatly enhanced sensitivity to fast neutrons. These two sensor heads are referred to as the Charged Particle Detector (CPD) and Fast Neutron Detector (FND), respectively. Despite its name, the CPD is also capable of measuring high-energy neutrons and γ-rays, as is MSL-RAD. ISS-RAD was flown to the ISS in December 2015 and was deployed in February 2016, initially in the USLab module. RAD was used as a survey instrument from January 2017 through May 2020, when the instrument was positioned in the USLab and set to a zenith-pointing orientation. The energetic particle environment on the ISS is complex and varies on short time scales owing to the orbit, which has a 51.6∘ inclination with respect to the equator and has had an altitude in the 400-440 km range in this time period. The ISS moves continuously through the geomagnetic field, the strength of which varies with latitude, longitude, and altitude. The orbit passes through the South Atlantic Anomaly (SAA) several times a day, where magnetically trapped protons and electrons produce large but transient increases in observed fluxes and absorbed dose rates. The environment inside the ISS is affected by the solar cycle, altitude, and the local shielding, which varies between different ISS modules. We report results for charged particle absorbed dose and dose equivalent rates in various positions in the ISS. In an accompanying paper, we report similar results for neutron dose equivalent rates obtained with the ISS-RAD Fast Neutron Detector.


Assuntos
Radiação Cósmica , Monitoramento de Radiação , Proteção Radiológica , Monitoramento de Radiação/métodos , Nêutrons , Prótons
2.
Life Sci Space Res (Amst) ; 39: 76-85, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37945092

RESUMO

We report the results of the first six years of measurements of so-called fast neutrons on the International Space Station (ISS) with the Radiation Assessment Detector (ISS-RAD), spanning the period from February 2016 to February 2022. ISS-RAD combines two sensor heads, one nearly identical to the single sensor head in the Mars Science Laboratory RAD (MSL-RAD). The latter is described in a companion article to this one. The novel sensor is the FND, or fast neutron detector, designed to measure neutrons with energies in the range from 200 keV to about 8 MeV. ISS-RAD was deployed in February 2016 in the USLAB module, and then served as a survey instrument from March 2017 until May 2020. Data were acquired in Node3, the Japanese Pressurized Module, Columbus, and Node2. At the conclusion of the survey portion of RAD's planned 10-year campaign on ISS, the instrument was stationed in the USLAB; current plans call for it to remain there indefinitely. The radiation environment on the ISS consists of a complex mix of charged and neutral particles that varies on short time scales owing to the Station's orbit. Neutral particles, and neutrons in particular, are of concern from a radiation protection viewpoint, because they are both highly penetrating (since they do not lose energy via direct ionization) and, at some energies, have high biological effectiveness. Neutrons are copiously produced by GCRs and other incident energetic particles when they undergo nuclear interactions in shielding. As different ISS modules have varying amounts of shielding, they also have varying neutron environments. We report results for neutron fluences and dose equivalent rates in various positions in the ISS.


Assuntos
Radiação Cósmica , Monitoramento de Radiação , Voo Espacial , Astronave , Nêutrons Rápidos , Monitoramento de Radiação/métodos , Nêutrons , Doses de Radiação
3.
Life Sci Space Res (Amst) ; 39: 86-94, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37945093

RESUMO

The energetic particle radiation environment on the International Space Station (ISS) includes both charged and neutral particles. Here, we make use of the unique capabilities of the Radiation Assessment Detector (ISS-RAD) to measure both of these components simultaneously. The Charged Particle Detector (CPD) is, despite its name, capable of measuring neutrons in the energy range from about 4 MeV to a few hundred MeV. Combined with data from the Fast Neutron Detector (FND) in the 0.2 to 8 MeV range, we present the first broad-spectrum measurements of the neutron environments in various locations within the ISS since an early Bonner-Ball experiment that was conducted before the Station was fully constructed. The data presented here span the time period from February 2016 to February 2022. In addition to presenting broad-spectrum neutron fluence measurements, we show correlations of the measured neutron dose equivalent with charged-particle dose rates. The ratio of charged-particle dose to neutron dose equivalent is found to be relatively stable within the ISS.


Assuntos
Radiação Cósmica , Monitoramento de Radiação , Nêutrons Rápidos , Astronave , Doses de Radiação , Monitoramento de Radiação/métodos , Nêutrons
4.
J Hazard Mater ; 129(1-3): 171-8, 2006 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-16298475

RESUMO

In this work, the effect of incorporation of M2+ species, i.e. Co2+, Mn2+ and Ni2+, into the magnetite structure to increase the reactivity towards H2O2 reactions was investigated. The following magnetites Fe3-xMnxO4, Fe3-xCoxO4 and Fe3-xNixO4 and the iron oxides Fe3O4, gamma-Fe2O3 and alpha-Fe2O3 were prepared and characterized by Mössbauer spectroscopy, XRD, BET surface area, magnetization and chemical analyses. The obtained results showed that the M2+ species at the octahedral site in the magnetite strongly affects the reactivity towards H2O2, i.e. (i) the peroxide decomposition to O2 and (ii) the oxidation of organic molecules, such as the dye methylene blue and chlorobenzene in aqueous medium. Experiments with maghemite, gamma-Fe2O3 and hematite, alpha-Fe2O3, showed very low activities compared to Fe3O4, suggesting that the presence of Fe2+ in the oxide plays an important role for the activation of H2O2. The presence of Co or Mn in the magnetite structure produced a remarkable increase in the reactivity, whereas Ni inhibited the H2O2 reactions. The obtained results suggest a surface initiated reaction involving Msurf2+ (Fe, Co or Mn), producing HO radicals, which can lead to two competitive reactions, i.e. the decomposition of H2O2 or the oxidation of organics present in the aqueous medium. The unique effect of Co and Mn is discussed in terms of the thermodynamically favorable Cosurf3+ and Mnsurf3+ reduction by Femagnetite2+ regenerating the active species M2+.


Assuntos
Óxido Ferroso-Férrico/química , Peróxido de Hidrogênio/química , Ferro , Cobalto , Compostos Férricos/química , Manganês , Níquel , Oxirredução
6.
Rev. chil. infectol ; 2(2): 121-7, dic. 1985. tab, ilus
Artigo em Espanhol | LILACS | ID: lil-104772

RESUMO

Se efectuó tomografía computarizada en 9 lactantes que presentaron meningitis aguda purulenta, complicados e ingresados en la Unidad de infecciosos del Servicio de Pediatría del Hospital de Valdivia en los últimos dos años. Se describen las indicaciones clínicas que se consideraron para la TAC. Los principales hallazgos observados en cada uno de estos casos fueron: hidrocefalia, colección subdural, atrofia cerebral, empiema subdural y desmielinización. Se hace mención de las ventajas que provee esta técnica no invasiva, entre las que se incluye un diagnóstico precoz y seguro de las complicaciones tempranas, algunas de las cuales son indicadoras de procedimiento quirúrgico


Assuntos
Meningite Meningocócica/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Doenças Desmielinizantes/etiologia , Empiema Subdural/etiologia , Hidrocefalia/etiologia , Meningite Meningocócica/complicações
7.
Rev. chil. infectol ; 2(2): 128-31, dic. 1985. tab
Artigo em Espanhol | LILACS | ID: lil-104773

RESUMO

Se comunican cuatro infecciones intrahospitalarias por A. calcoaceticus, en tres lactantes y un escolar, pesquisadas durante el primer semestre de 1984 en el Servicio de Pediatría del Hospital Regional de Valdivia. Entre los factores predisponentes encontrados en los cuatro casos destacan: hospitalización superior a 10 días, hidratación intravenosa, instrumentación y enfermedades anergizantes. Los cuadros clínicos observados correspondieron a septicemia en tres casos e infección urinaria en otro. El patrón de sensibilidad antibiótica fue similar en las cuatro cepas aisladas, obteniéndose una respuesta clínica satisfactoria frente a aminoglicósidos en tres de los cuatro pacientes


Assuntos
Infecções por Acinetobacter/tratamento farmacológico , Acinetobacter/isolamento & purificação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...